Data Acquisition
Supports 100+ protocols covering meters, PLCs, DCS, and CNCs with unified Modbus, BACnet, and OPC UA data services.
GC helps engineers configure, monitor, and simulate LM Gateway products before field deployment, reducing commissioning time and setup uncertainty.

Supports 100+ protocols covering meters, PLCs, DCS, and CNCs with unified Modbus, BACnet, and OPC UA data services.
Aggregate query APIs and up to 128GB local edge time-series storage keep field data available when networks are unstable.
MQTT, HTTP, and database clients push data to open IoT platforms without locking teams into a single cloud.
Built-in H5 Web SCADA enables browser-based visualization for local dashboards and equipment status.
Event management through SMS, instant messengers, and email with customizable trigger and clearance conditions.
Function libraries and custom logic scripts help engineers adapt gateway behavior to project requirements.
Collects the whole configuration — acquisition, forwarding, storage, alarms and scripts — into one project; once downloaded, the project runs independently on the gateway.
Full gateway lifecycle management:
Configure the acquisition channel, devices, data points and internal points of each protocol. Built-in LMGateway drivers cover meters, PLCs, DCS and CNC equipment across 100+ protocols, with public examples including Modbus, DLT645, IEC 104 and standard drivers such as BACnet.
Common settings:
Filters out abnormal data caused by communication faults or interference, for example through exception value filtering and data substitution.
Add a target point (user point) and link it to several source points (acquisition points). Controlling that user point from the host system then drives every linked source point for efficient synchronised control and centralised management.
Configure forwarding protocols to serve data to SCADA, MES, host systems or other platforms, connecting field devices with the layers above them.
Supported capabilities:
Configure the gateway-side historical and time-series storage strategy and query the stored results.
LM Gateway supports edge time-series storage of up to 128 GB and provides aggregated query APIs.
Configure cloud services over MQTT — Alibaba Cloud Alink, Tlink, private clouds and other MQTT platforms. HTTP upload and database client writes are also supported, pushing acquired data to open IoT platforms.
Configurable items:
Configure alarm conditions, recovery conditions, alarm levels and notification methods; trigger and recovery events are recorded separately, and alarm data can be stored and queried.
The gateway supports SMS, DingTalk and WeCom notification channels.
A built-in script editor and function library support custom logic control, data conversion, alarm linkage and calculations.
API documentation and demo examples are provided; scripts run during project simulation or on the gateway at runtime.
Inspect gateway status online and quickly locate channel, device and protocol exchange problems.
Includes:
Run the project on a PC without an LM Gateway to validate acquisition points, forwarding, scripts, alarms and tasks before downloading it to the device.
Without a license the project can be simulated for 2 hours — useful for feature evaluation, pre-sales demos and early on-site commissioning.