Modbus Gateway

One side polls RS-485 field devices as a Modbus RTU master, the other side serves register data as a Modbus TCP server.Channels, point table and diagnostics all live in the device's built-in web pages, with no configuration software to install.

  • Modbus RTU acquisition ↔ Modbus TCP server
  • Several host systems access one gateway concurrently
  • Channels, point table and diagnostics configured in the browser
LM PGM2M series Modbus gateway product view

Features

RTU and TCP interworking

One side polls RS-485 slaves as a Modbus RTU master, the other side answers host systems as a Modbus TCP server, with function codes and register addresses mapped one to one.

Concurrent multi-master access

Several host systems can connect and poll at the same time; the gateway dispatches requests separately, so no dedicated gateway is needed for each system.

Register-level mapping

Channel, slave address, function code and register address are mapped item by item; data type and byte order are selectable, and floating-point values are restored in the correct word order.

Adjustable polling strategy

Baud rate, parity and timeout retries are set per channel, while polling cycles and slave groups are adjusted independently, so a slow device does not hold up the whole bus.

Configuration in the browser

Channels, point table, service parameters and diagnostics are handled in one web interface, with batch import and export of the point table and configuration backup.

Automatic recovery after a drop

Configuration is stored on the device and loaded automatically after a restart; serial or network interruptions reconnect automatically, and points refresh with the latest data once the link returns.

Modbus gateway connected to a Modbus TCP master on one side and to power meters, water meters and field devices over RS-485 on the other

Diagnostics

Communication statistics

Requests, responses, timeouts and error codes are counted per channel, distinguishing line interference, mismatched baud rates and slave address conflicts.

Point monitoring

Points are grouped by channel and show the latest value, update time and communication status; an abnormal point can be traced to a specific slave and register.

Panel indicators

PWR / RUN / Tx / Rx indicate power, operation and bus traffic, so a faulty segment can be judged without any software.

One-touch factory reset

The FUN key on the panel and the web interface can both restore factory settings, so a mis-configured IP or serial parameter does not require dismantling the device.

Product Range

LM PGM2M-101 Modbus gateway

LM PGM2M-101

Interface
1 × RS-485 · 1 × Ethernet
Capacity
256 data points
LM PGM2M-201 Modbus gateway

LM PGM2M-201

Interface
2 × RS-485 · 1 × Ethernet
Capacity
512 data points
LM PGM2M-401 Modbus gateway

LM PGM2M-401

Interface
4 × RS-485 · 1 × Ethernet
Capacity
512 data points