LM Gateway 414-B protocol conversion gateway, based on a solid hardware platform design, a complete software kernel. Provide 4 RS-485 serial ports, 2 10/100 Mbps Ethernet ports, gateway embedded Modbus, DLT645 and other data acquisition drivers, provide private protocol driver integration, gateway as BACnet IP, BACnet MS/TP server provides data externally
Buy online
CPU | 4 core A9, 1.4GHz |
RAM | 512MB |
Nand Flash | MLC eMMC 4GByte eMMC |
Serial port | RS-485X4 |
Network port | 2 100M/10M Ethernet interfaces |
Power | DC9V~36V |
Total Weight | 230g |
Enclosure rating | IP51 |
Mechanical Dimensions | 135mm×85mm×29mm(L×W×H) |
Mechanical installation | DIN rail card slot fixing |
FUN | Long press to restore factory settings |
Power Consumption | The maximum power consumption of the motherboard is ≤3W |
Operating temperature | -30~70℃ |
Working relative humidity | 20~90%non-condensing |
Instrumentation | Data acquisition driver | Serial port | Network port |
Modbus protocol | Modbus RTU | Modbus TCP, Modbus RTU_over_TCP | |
DLT645 protocol | DLT645-1997, DLT645-2007 | / | |
CJ188 protocol | CJ188 | / | |
Mbus | MBus_EnergyMeter, MBus_EN1434 | / | |
PLC | Mitsubishi Agreement | Mitsubishi Fx3U | / |
Mitsubishi Fx485 | / | ||
Mitsubishi_QBinary | / | ||
Siemens protocol | Siemens S7-200 PPI | Siemens S7-200 Network | |
/ | Siemens S7-300 Network | ||
/ | Siemens S7-400 Network | ||
/ | Siemens S7-1200 Network | ||
/ | Siemens S7-1500 Network | ||
AB | / | AB NET | |
OMRON Protocol | OMRON_HOSTLINK | OMRON_FINS | |
Industrial control and automation interface standards | OPC protocol | / | OPC UA, OPC DA, OPC XML DA |
Substation communication standard | IEC protocol | / | IEC104 |
Non-standard protocol | Instrumentation | Yiling temperature controller | / |
dlt645 JX Digital | / | ||
dlt645-2007 extended protocol | / | ||
Jiangsu Runyi Water Meter | / | ||
HL-MODBUS protocol | / | ||
CJ/T133-2012 IC card water meter | / | ||
DLT645-Fee Control | / | ||
CJ/T133-2012 MBus IC card water meter | / | ||
ModbusRTU_TancyA1 | / | ||
Allen_Bradley_DF1 | / | ||
modbus Shendong 43 | / | ||
CJ188贵翔 | / | ||
Beijing Mingcheng Zhonghui Sunshade Curtain | / | ||
SGA400 | / | ||
DEET-BUS | / | ||
Internet interface | Internet collection | / | mqtt client subscription |
/ | Gold map weather forecast | ||
/ | Zhejiang Dahua HTTP | ||
/ | HTTP collection | ||
/ | Air Quality |
-
The gateway provides data to the BACnet IP and BACnet MS/TP server
Support AI, AO, AV, BI, BO, BV, MSI, MSO, MSV and other attributes, configurable data units
Support for Who-Is and I-Am services, cov subscription, read, write, etc.
The gateway provides an http server, which supports two common methods of GET and POST.